Products · Line P

P Series

Parallel-before-Series battery storage at utility scale — 8.2 MWh and 3.6 MW per enclosure in the flagship P8000, engineered for AI data centers and grid-scale deployments, run by StorOS™.

TeraStor P8000
P8000 · 8.2 MWhComing 2027

8.2 MWh

Dischargeable energy per enclosure

3.6 MW

Rated DC power per unit

IP66

Ingress protection, outdoor-rated

LFP

Cell chemistry, liquid cooled

Technical Specifications

One Enclosure, Utility Scale

Thermal runaway limited to the individual cell, far exceeding UL9540A and NFPA requirements — and a parallel architecture that keeps the unit running when a cell fails.

P8000

P8000

UL 9540UL 9540AUL 1973NFPA 69NFPA 855UN 38.3

8.2 MWh dischargeable per enclosure — the flagship of the P line, deployed at utility and data-center scale.

Dischargeable Energy8.2 MWh
Rated DC Power3.6 MW
Output Voltage Range1,164-1,500 VDC
Auxiliary Power30 kW max
Auxiliary Input Voltage480V 3P
Dimensions (WxDxH)27'x12.5'x8' ft
Ingress protectionIP66
CoolingLiquid
Cell ChemistryLFP
Operating Temperature Range-20 to 50 C
Warranty5 yrs Std - 20 yrs Ext.
Download Datasheet

Product Line P

Parallel Before Series, By Design

Product Line P is built on TeraStor's patented Parallel-before-Series architecture, culminating in the flagship P8000 — 8.2 MWh of dischargeable energy and 3.6 MW of DC power in a single 27-foot enclosure.

Paralleling at the cell level increases capacity, availability and reliability: a failed cell derates the unit instead of disabling it, and thermal runaway is limited to the individual cell — far exceeding the requirements of UL9540A and NFPA standards. Every enclosure ships on StorOS™.

P Series product line

Recommended Deployments

Where the P Series Fits

The solution segments that run on P Series hardware.

Data Centers

P8000

Dedicated storage for AI campuses and mission-critical facilities — ride-through, peak shaving and grid-interactive dispatch behind one interconnect, with 99% system availability, guaranteed.

  • 99% system availability, guaranteed
  • Cell-level thermal runaway containment: far exceeding UL9540A and NFPA requirements
  • IP66 outdoor enclosures: no battery building on the campus
  • StorOS™ dispatch around compute load and tariff windows
Learn More
Data Centers

Utilities

P8000

Front-of-meter capacity at 8.2 MWh per pad position — fewer enclosures, fewer interconnects and less balance-of-plant per megawatt-hour installed.

  • Highest energy density in the fleet: 8.2 MWh per 27-foot enclosure
  • Parallel-before-Series availability: a failed cell derates the unit, never disables it
  • 20-year extended warranty option on every unit
  • Territory-wide telemetry via StorOS™ Global Overview and Fleet Overview
Learn More
Utilities

Get Started

See StorOS on Your Fleet

Bring one site or a mixed fleet of someone else's hardware — we'll stand up a live demo against your telemetry.

Solutions customized to your site's needs
Works with your existing hardware — TeraStor or third-party
See StorOS live on a real fleet

Get in touch